Pass Your Project-Planning-Design Exam With An Excellent Score
NCARB certification Project-Planning-Design exam is one of the many IT employees' most wanting to participate in the certification exams. Passing the exam needs rich knowledge and experience. While accumulating these abundant knowledge and experience needs a lot of time. Maybe you can choose some training courses or training tool and spending a certain amount of money to select a high quality training institution's training program is worthful. Lead2PassExam is a website which can meet the needs of many IT employees who participate in NCARB Certification Project-Planning-Design Exam. Lead2PassExam's product is a targeted training program providing for NCARB certification Project-Planning-Design exams, which can make you master a lot of IT professional knowledge in a short time and then let you have a good preparation for NCARB certification Project-Planning-Design exam.
Are you still worried about the actuality and the accuracy of the Project-Planning-Design exam cram? If you choose us, there is no necessary for you to worry about this problem, because we have the skilled specialists to compile as well check the Project-Planning-Design Exam Cram, which can ensure the right answer and the accuracy. The pass rate is 98%, if you have any other questions about the Project-Planning-Design dumps after buying, you can also contact the service stuff.
>> Project-Planning-Design Sure Pass <<
Topping Project-Planning-Design Practice Quiz: ARE 5.0 Project Planning & Design (PPD) Supply You the Most Veracious Exam Brain Dumps - Lead2PassExam
We all have the right to pursue happiness. Also, we have the chance to generate a golden bowl for ourselves. Now, our Project-Planning-Design practice materials can help you achieve your goals. As we all know, the pace of life is quickly in the modern society. So we must squeeze time to learn and become better. With the Project-Planning-Design Certification, your life will be changed thoroughly for you may find better jobs and gain higher incomes to lead a better life style. And our Project-Planning-Design exam questions will be your best assistant.
NCARB Project-Planning-Design Exam Syllabus Topics:
Topic
Details
Topic 1
Topic 2
Topic 3
Topic 4
Topic 5
NCARB ARE 5.0 Project Planning & Design (PPD) Sample Questions (Q95-Q100):
NEW QUESTION # 95
An owner requests full height, motorized solar shades for the lobby curtainwall.
Click on the area of the section detail where the shade should be installed so that it is concealed from the lobby.
Answer:
Explanation:
Explanation:
The solar shade should be installed within the ceiling recess above the curtainwall, behind the horizontal soffit-specifically in the void space between the top of the curtainwall glazing and the structural ceiling soffit (the shaded area immediately above the curtainwall glass in the section).
NEW QUESTION # 96
A new four-story apartment building is being designed on a site that has solid bedrock subsurface conditions.
The client requested the lowest cost of installation, highest energy efficiency, the shortest round trip time, and minimized loss of usable building space.
Which elevator type should the architect recommend?
Answer: A
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Given the constraints:
Lowest cost of installation and minimized loss of usable space favor elevators that don't require a separate machine room.
Machine-roomless elevators (D) have compact machinery integrated within the hoistway, reducing space needs and construction costs.
Hydraulic elevators (A, C) require pits and often larger machine rooms, and are less energy efficient and have slower round trip times compared to traction types.
Gearless traction elevators (B) provide excellent speed and efficiency but usually require machine rooms, increasing cost and space.
Thus, machine-roomless elevators balance cost, efficiency, space, and speed best for mid-rise residential buildings.
References:
ARE 5.0 PPD - Building Systems and Assemblies, Vertical Transportation
The Architect's Handbook of Professional Practice, 15th Edition - Elevators and Conveying Systems
NEW QUESTION # 97
An existing building containing the maximum allowable area may be extended horizontally provided the extension is separated from the existing building by which one of the following?
Answer: A
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
According to the International Building Code (IBC) and reflected in the NCARB Project Planning & Design guidelines, when an existing building has reached the maximum allowable floor area, horizontal extensions (additions) can be made only if there is a proper separation between the existing structure and the new addition. This separation must prevent fire spread and protect structural integrity.
A fire wall is a continuous, fire-resistive barrier designed to prevent the spread of fire between adjacent buildings or different parts of a building. It must have structural stability under fire conditions and can allow the two portions of the building to be treated as separate structures for area calculations, effectively permitting expansion beyond the allowable area of a single building.
Fire-rated shutters (Option A) are movable devices used for compartmentation but are not intended for permanent separation of building areas.
Outside space separation of at least 10 ft (Option B) is generally insufficient for full area separation unless it meets specific fire-resistance rating and distance requirements that typically exceed 10 feet.
Water curtains (Option D) are active fire protection devices but are not substitutes for passive separations required by code to extend allowable building area.
Thus, the correct method to extend a building beyond its maximum allowable area is to separate it with a fire wall, as per NCARB and IBC provisions.
References:
ARE 5.0 PPD - Codes and Regulations, Building Area and Occupancy Separation IBC 2018, Chapter 7: Fire and Smoke Protection Features The Architect's Handbook of Professional Practice, 15th Edition - Fire Protection
NEW QUESTION # 98
On the site plan, the Phase I building is a 24-hour emergency veterinary clinic. The Phase II building is a boarding kennel for dogs and cats. The cat enclosures will face north for views of the wetlands. Eventually, a landscape architect will design a memorial garden on the northwest area of the site.
The architect needs to locate a service drive for the property and wants to minimize the impact of construction on site vegetation and wildlife.
Click on the property line location on the site plan to indicate the appropriate location for the service drive.
Answer:
Explanation:
Explanation:
east side (Pine Street)
* Locating the service drive along the east side (Pine Street) minimizes disturbance to the wetlands area (northwest part of the site) and existing trees concentrated mostly in the southwest and northwest areas.
* This placement keeps the service drive away from the sensitive wetlands and the planned memorial garden on the northwest, preserving wildlife habitats and mature vegetation.
* It also provides convenient access for service vehicles without crossing or fragmenting critical site features.
* The east side is adjacent to an existing road (Pine Street), making it logical for service access and reducing new disturbance.
This approach aligns with NCARB ARE 5.0 Project Planning & Design guidance for site design prioritizing environmental preservation and minimizing construction impact on sensitive natural areas.
NEW QUESTION # 99
An architect is designing a mixed-use building and must provide fire separation between the various use types.
Which properties must be considered to meet the fire separation requirements? Check the three that apply.
Answer: B,D,E
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
To meet fire separation requirements, the following must be considered:
Occupancy type (B): Different uses have different fire hazard classifications influencing separation.
Wall assembly materials (D): Materials define fire resistance ratings.
Wall to structure connection (A): Proper connection maintains fire separation integrity.
Air changes (C) relate to ventilation, not separation.
Exit corridor length (E) and building orientation (F) affect egress and solar exposure, not fire separation.
References:
ARE 5.0 PPD - Codes and Regulations, Fire Separation
The Architect's Handbook of Professional Practice, 15th Edition - Fire-Resistive Construction
NEW QUESTION # 100
......
The client only needs 20-30 hours to learn our Project-Planning-Design learning questions and then they can attend the test. Most people may devote their main energy and time to their jobs, learning or other important things and can’t spare much time to prepare for the test. But if clients buy our Project-Planning-Design Training Materials they can not only do their jobs or learning well but also pass the test smoothly and easily because they only need to spare little time to learn and prepare for the Project-Planning-Design test.
Latest Test Project-Planning-Design Experience: https://www.lead2passexam.com/NCARB/valid-Project-Planning-Design-exam-dumps.html
لا توجد منتجات في سلة المشتريات.
عزيزي المتدرب، إذا واجهت أية مشكلة تواصل معنا ولا تتردد